RCDC - Option to carry out Combined Footing Design and Detailing in RCDC
There should be a feature in RCDC whereby you can group selected footing for combine footing design and detailing. Or, after RCDC is finish footing designs and the distance between adjacent footings are below a specified minimum, then RCDC should ...
Moving load in vertical plane and horizontal plane as well.
As of now, moving load feature is available only in vertical plane. But moving load in horizontal plane isn't available yet.
But, as per industry demand, moving load to be applied longitudinal and transverse direction, simultaneously.
Staad pro s...
STAAD FOUNDATION BEARING PRESSURE DISPLAY FOR UPLIFT CASES
Currently in staad foundation max/min bearing pressure is shown only for the compression cases.Incase the minimum pressure is governed in uplift case the same is not shown in the summary table.Same can be updated in upcoming revisions.Also the bea...
Dear Sir / Madam, Steel Auto Drafter is not giving beam presentation as per Releases provide in Analytical Modelling. Please check attached screenshot for your ready reference. Steel AutoDrafter drawings should be as per Release and Analytical mod...
over 1 year ago
in STAAD.Pro
7
Future consideration
Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.
STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
For pile cap design it will be helpful to include summary of pile forces for all the piles in the calculation report. Current version only provides a summary table of maximum pile reaction for service load cases but not all the piles. If I have to...
RCDC - Beam Design - Long term deflection check should be available
For the structures like Metro railway station and Industrial buildings, Clients are demanding to perform the long-term deflection check of the beam. RCDC should allow to perform the long-term deflection check for the beams selected by the user. Ge...
Dear Colleagues, // STAAD.Pro CONNECT Edition - Version 22.12.00.142 // there was a situation where we had to find out the lateral forces due to wind on a light pole (tapered profile) and provide suitable support for the same. Wind was applied usi...
about 2 years ago
in STAAD.Pro
1
Future consideration
Allow an option to include Failed Member list in the report even when there are no failed members
In the new 2023 version, the new report builder doesn't allow you to include the failed member list when there aren't any failed members. v22 did allow for that and would report there are no failed members. Which was an easy concise way of saying ...
over 1 year ago
in STAAD.Pro
1
Future consideration