Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 456

Table providing summary of slenderness ratio's of structural steel members

Helps in assessing the actual slenderness ratio of each member.Also, such table can be used to upgrade to next size for better load carrying capacity.
almost 2 years ago in STAAD.Pro 1 Will not implement

HAT SECTION WITH LIPS

Kindly make provision for Hat section with Lips( straight lip and inclined lip) in the section database. Please make it such a way that if we enter the depth, width, thickness and give "generate" and all the properties gets generated automatically...
almost 3 years ago in STAAD.Pro 4 Future consideration

Beam utilization listing with drop down box

The "actual ratio" button in postprocessing mode is not working for a lot of users in Subsea7. This button is supposed to re-arrange beam utilizations from default beam number order, to utilization ascending order, and is very helpful. The problem...
12 months ago in STAAD.Pro 2 Needs review

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
6 months ago in STAAD.Pro 1 Future consideration

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
6 months ago in STAAD.Pro 1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
6 months ago in STAAD.Pro 1 Needs review

STAAD PRO TO 3D PDF

There should be a way to convert STAAD model to 3D pdf. It will become easy for designers to hover over the model and get clear view of the geometry while modelling in 3D softwares. Inspite of inputs provided, they will have access to 3D pdf where...
over 1 year ago in STAAD.Pro 4 Already exists

Add Back to back properties of CF member

Kindly add the back-to-back properties of Lysaght C section (combinedly it becomes I- section) ,it is widely used in cold form structures.
almost 2 years ago in STAAD.Pro 1 Future consideration

In India we are using HAT section with lip but in staad pro we are not able design this section and it create lots of problem to all users in India to convince clients. So, Please add this section property in your section database.

No description provided
12 months ago in STAAD.Pro 1 Will not implement

Add NZS 1170.5 code to Seismic Codes in STAAD

STAAD does not have NZS 1170.5 in its Seismic Codes. Users in ANZ uses custom spectrum and factored it up to match the base shear. Adding this code will help the users in ANZ work directly with the NZ code and thus speed up their productivity. Use...
about 3 years ago in STAAD.Pro 1 Future consideration