Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 564

Staad Foundation Advance V9

For pile cap design it will be helpful to include summary of pile forces for all the piles in the calculation report. Current version only provides a summary table of maximum pile reaction for service load cases but not all the piles. If I have to...
about 1 year ago in STAAD Concrete 2 Planned

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
about 3 years ago in STAAD.Pro 4 Future consideration

Calculate section properties when adding new shape to database

Two things here:Have the ability for STAAD (in the physical modeler) to calculate the section properties when entering a new shape into an existing database. For example, I'm adding a new hat channel into the AISI cold formed Profiles database. In...
about 3 years ago in STAAD.Pro 4 Future consideration

RAM DOES NOT SUPPORT TO ADD STIFFENER TO PINNED BASE PLATE?

It is hoped that the method of adding stiffeners in the design of American standard column bases can be increased, and it is best to be customizable. For example, extending plate stiffeners can be set on the web of the I-beam.
4 months ago in STAAD.Pro 0 Needs review

SFA Foundation use uniform (average) Effective Bearing Pressure per AASHTO 10.6.1.4

Currently, SFA uses the highest corner pressure to design the foundation size bearing on soil. Please revise the SFA program to have an option for a soil supported foundation (versus a rock supported foundation) and provide revised foundation sizi...
about 2 years ago in STAAD Concrete 2 Needs review

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
about 2 years ago in STAAD.Pro 3 Future consideration

Direct Analysis Method with Tension-Only members

Just as the title. To be able to analyze a structure with Tension-Only members using the Direct Analysis Method.
over 2 years ago in STAAD.Pro 1 Future consideration

Show Pile Unities in Results

Show pile unities in compression, shear and tension without having to click on a particular item in result Graphics in STAAD Foundation Advanced 2024.
4 months ago in STAAD Concrete 0 Needs review

Connections design using angle & channel connections should be added in ram connection

Connections design using angle & channel connections should be added in ram connection
4 months ago in STAAD.Pro 0 Needs review

when standard sections are used instead of legacy analysis cant be imported to RCDC

In the new staad edition standard sections were added in addition to legacy.but when standard scetions were used, the analysis file cant be imported to RCDC.please solve this as there are new standard sections added which are not available in legacy.