Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 426

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3?

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3? Thanks
over 1 year ago in STAAD Concrete 0 Needs review

Multiple design parameters results in post processing window for Indian code IS 800-2007 is requested.

This will reduce the tedious process of turning on and off each design parameter from editor file and then running the full input file again multiple times. If this can be implemented for AISC-360 then it shall be implemented for other codes also.
11 months ago in STAAD.Pro 1 Future consideration

MEMBER FORCES - GLOBAL Coordinate System

STAAD cannot report Beam Results in the Global Coordinate Systems in the UI Results Table. However, it is capable of printing Member Forces using the Global Coordinate System to the Analysis Report. This hinders downstream processes that require t...
almost 2 years ago in STAAD.Pro 4 Future consideration

Staad Pro does not include Seismic load NBCC 2015

Dear All, I highly recommend to include calculation of seismic load using NBCC 2015. I see it as a big gap in Staad Pro not to include Seismic loading using NBCC 2015 Thanks a lot
about 4 years ago in STAAD.Pro 1 Future consideration

Scale factor for displacement quantities in response spectrum analysis as per IS 1893:2016 amendment no-2 (additional clause 7.7.3.2) regarding

It is understood that while performing response spectrum analysis, the scale factor (V_b/V_B ) Where,V_b=Equivalent static base shear,〖 V〗_B Response spectrum base shear), is automatically accounted for calculation of design base shear. But,this s...
6 months ago in STAAD.Pro 0 Needs review

Add load to the node/beam/element group using OpenSTAAD

Hi, I have an OpenSTAAD program that generates groups and that applies loads to the elements/beams/nodes in those groups. However I'd like to apply the load to the group directly using openSTAAD as you can in the STAAD Command File? What I want to...
11 months ago in STAAD.Pro 1 Future consideration

RDCD limitations need to be takeup

While doing design of beam using Staad file interface at each level selected beams need to be design as per Staad design envelope. 1) Along X-direction grid design will be one envelope. 2) Along Z-direction grid design will be second envelope. 3) ...
6 months ago in STAAD Concrete 1 Needs review

water tank design with ACI code

the software need to design water tank with ACI code in RCDC,so we hope to add Aci code to it.
over 2 years ago in STAAD Concrete 2 Needs review

Provide wind generation on Fireproof Members

STAAD does not consider the additional width of the fireproofed members; producing underestimated wind generated loads for open structures like piperacks. Please include this feature as this would make several of my colleagues happy.
about 5 years ago in STAAD.Pro 5 Future consideration

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.