Moving Loads Acting in Horizontal Directions

Provide the ability to have horizontal moving loads in addition to the vertical loads. For example, ASCE 7 requires cranes to be designed for vertical loads and horizontal loads. It would be great if STAAD had the ability to have both the vertical...
over 2 years ago in STAAD.Pro 3 Future consideration

Combined profile of a wide flange and channel as a single object

For Inclusion of built up section in standard I section combination with Channel section on top flange, which is widely used for gantry girder.
about 2 years ago in STAAD.Pro 5 Already exists

Aluminium design checks per BS EN 1999

Eurocode checks for aluminium members
4 months ago in STAAD.Pro 0 Needs review

RCDC -Foundation design - Multiple Soil layers and Dispersed soil weight to be considered in the Stability checks -Buoyancy and overturning

For the foundation design, Buoyancy and overturning stability checks are performed. Presently Soil above the footing area is considered for the stability checks. The software should allow the user wants to consider the dispersed soil weight for th...
over 2 years ago in STAAD Concrete 0 Needs review

Include Indian Design Codes

your soft does not support codes for designing as per Indian Codes request if you could incorporate the same since the software is a wonder full product
8 months ago in STAAD Concrete 1 Needs review

Slab deflection plots

Currently the only way to check the deflection of a slab is to review the deflected shape of the shells' mesh, or in the tabulated results. It would be very useful if the contour plots for shells included the option to contour deflections as well ...
over 1 year ago in STAAD.Pro 2 Future consideration

Steel AutoDrafter: Customized Offset Distance

Steel Auto-Drafter draws member releases with a 20mm offset by default. The user would like to set this offset distance to an arbitrary distance. Additionally, the user would like to set separate distances for each of the following members: ...
almost 3 years ago in STAAD.Pro 6 Future consideration

Built-up tapered section name

All tapered section name shows as a tapered . its very useful if staad pro show the tapered section show the section in the display- Tapered I- 300x6+200x8+150x8 if its uniform web depth Tapered I- (300-750)x6+200x8+150x8 if its tapered web depth ...
about 1 year ago in STAAD.Pro 2 Future consideration

Beam - edit reinf for grouped beam - issue

This issue exists in all design codes.beams without grouping, edit reinforcement works properly. if beams are grouped, software unable to change the reinforcement.for grouped beams, quick detail and copy paste reinforcement works fine. Service cas...
4 months ago in STAAD Concrete 0 Needs review

Combined wall design taking more time for specific case

refer Service case Service Case 1494311: [CS0270621] Combined wall design taking more timeAs alternate solution is available, it is marked as Low severity.