Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
almost 3 years ago
in STAAD.Pro
4
Future consideration
SFA Foundation use uniform (average) Effective Bearing Pressure per AASHTO 10.6.1.4
Currently, SFA uses the highest corner pressure to design the foundation size bearing on soil. Please revise the SFA program to have an option for a soil supported foundation (versus a rock supported foundation) and provide revised foundation sizi...
Calculate section properties when adding new shape to database
Two things here:Have the ability for STAAD (in the physical modeler) to calculate the section properties when entering a new shape into an existing database. For example, I'm adding a new hat channel into the AISI cold formed Profiles database. In...
almost 3 years ago
in STAAD.Pro
4
Future consideration
In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.
There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
about 2 years ago
in STAAD.Pro
3
Future consideration
Add to STAAD Physical Modeler Vehicle/ Moving Loading
Physical Modeler Loading should include Moving Load /Vehicle. If you are following Physical modeler workflow there is no Vehicle or Moving load options, which is only allowed thru Analytical Model and to use that feature, only way would be to drop...
As per Chinese code design, we suppose to create lot of design parameter to perform the design. it is taking lot of time for controlling all the design parameter. can you make it simplified like regular STAAD pro design?
Ai-Chat GPT can be used in Staad Pro for calculating Gust factors, which otherwise involve a lot of complicated formulas. Also, Reports can be presented in better ways with less time.
All tapered section name shows as a tapered . its very useful if staad pro show the tapered section show the section in the display- Tapered I- 300x6+200x8+150x8 if its uniform web depth Tapered I- (300-750)x6+200x8+150x8 if its tapered web depth ...
Moving load in vertical plane and horizontal plane as well.
As of now, moving load feature is available only in vertical plane. But moving load in horizontal plane isn't available yet.
But, as per industry demand, moving load to be applied longitudinal and transverse direction, simultaneously.
Staad pro s...