Turkish Building Earthquake Code 2018 and TS 500

Türkiye de yaşayan mühendislerin programlarınızı kendi ülke standart ve kurallarına göre daha rahat kullanabilmeleri ve bunun paralelinde programlarınızın kullanım oranlarının artması doğrultusunda eklenmesi yaralı olacaktır.
11 months ago in STAAD.Pro 4 Future consideration

Turkish Building Earthquake Code 2018 for steel structures

Betonarme binaların projelendirmesi ile birlikte çelik binaların projelendirilmesinde de kendi ülke standart ve kurallarını kullanmak, mühendislerimiz için kolaylık ve rahatlık sağlayacak, programlarınızın ülkemiz içerisinde kullanımının yaygınlaş...
11 months ago in STAAD.Pro 3 Needs review

Member property display units- Shift+X

In spite of selecting Metric units for member section properties at the beginning of a new model (considering Indian codes), while checking the member sections during modelling and analysis, the member properties are getting displayed in FPS units...
5 months ago in STAAD.Pro 1 Already exists

It is hoped that the number of decimal places for the section thickness display can be increased to three, or the display unit of the section can be controlled.

No description provided
5 months ago in STAAD.Pro 1 Needs review

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
over 1 year ago in STAAD.Pro 3 Future consideration

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
almost 2 years ago in STAAD.Pro 7 Future consideration

Consider IS:3370 in RCDC for water tank design.

Currently RCDC works only in Euro code for water tank.. my suggestion is please consider IS:3370 for water tank design.
almost 2 years ago in STAAD Concrete 1 Needs review

The name of the load can be modified

When there are many types of load definitions, it is difficult to distinguish which one each load is. If you can customize the name, it will be easier to distinguish and verify
11 months ago in STAAD.Pro 5 Already exists

Add fire calculation in staad.pro

according to GB 51249-2017, steel structure needs to do the fire calculation and corresponding design. There are more and more security reviews about fire calculation, therefore it's necessary to add these content in staad.pro.
11 months ago in STAAD.Pro 1 Future consideration

Waffle /Grid slab and flat slab

Heavy loaded structures...
over 2 years ago in STAAD.Pro 3 Future consideration