Pedestal Editing STAAD Foundation Advanced 2024.

Please include the ability to edit the pedestal height in footings created from STAAD Pro reference files. Currently, editing is blocked after defining "Top Level," forcing footing remodeling. This limitation impacts design efficiency and accuracy...
13 days ago in STAAD Concrete 0 Needs review

STAAD Pro Connection Design: Comprehensive Reinforcement and Code Validation for Base Connections

Significant improvements to the "Connection Design" module of STAAD Pro are requested to enhance safety and efficiency in the design of base plate connections. This would be achieved through: Advanced Concrete Verifications: Implement comprehensiv...
15 days ago in STAAD Concrete 0 Needs review

Automatic Linking of Connections in Connection Designer with Steel AutoDrafter

I would like to suggest a significant improvement to the software. Currently, marking each connection one by one in engineering drawings is time-consuming and prone to errors. It would be extremely useful to link the connections generated in Conne...
15 days ago in STAAD.Pro 0 Needs review

Cold form section outside the standard library not designed in STAADpro as per IS801

STAADpro is not able to design cold form section outside the standard library or any user defined cold form section as per IS801. This is severe limitation as many users are using sections of their choice which are not in the library. This is espe...
1 day ago in STAAD.Pro 0 Needs review

Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
1 day ago in STAAD.Pro 0 Needs review

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
1 day ago in STAAD.Pro 0 Needs review

Design of Various type of Ground Level and Overhead Water tanks as per IS3370

Please inform the date of release of staad pro/RCDC for Design of Various type of Ground Level and Overhead Water tanks as per IS3370
4 days ago in STAAD Concrete 1 Needs review

staad foundation designing, hoped that desinger can specify any bar diameter and spacing in any code desingig

In staad foundation designing, hoped that desinger can specify any bar diameter and spacing when configuring rebar, rather than selecting the diameter and spacing provided by the software. It is a very useful feature. Other software can also achie...
5 days ago in STAAD Concrete 0 Needs review

STAAD.Pro AISC/CSA Code Checks - Eccentric Axial Specification

There is currently no way, other than directly adding rigid body members with the necessary releases, to simulate an an axial angle or tee member (brace) under eccentric axial load. This causes a high amount of manual calculations to determine the...
21 days ago in STAAD.Pro 0 Needs review

STAAD UNL,LY,LZ,KY,KZ.

I am suggesting STAAD to implement new features for users, which will make the users use a short time in steel design. 1. As we know, sometimes we may have a secondary beam where this beam will create a node in the primary beam. Now, to make the s...
about 1 month ago in STAAD.Pro 0 Needs review