Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 497

Staad Pro does not include Seismic load NBCC 2015

Dear All, I highly recommend to include calculation of seismic load using NBCC 2015. I see it as a big gap in Staad Pro not to include Seismic loading using NBCC 2015 Thanks a lot
over 4 years ago in STAAD.Pro 1 Future consideration

SLANT BEAM DESIGN IN RCDC

May you please update the design of Slant beam in RCDC,as you may have a building has a certain slope from one grid to another
over 4 years ago in STAAD Concrete 0 Future consideration

Provide wind generation on Fireproof Members

STAAD does not consider the additional width of the fireproofed members; producing underestimated wind generated loads for open structures like piperacks. Please include this feature as this would make several of my colleagues happy.
over 5 years ago in STAAD.Pro 5 Future consideration

Universal Setting for Design Results Colour

It would be useful to be able to a universal setting for different colors for different range of utilization ratios in the model to visually inspect. Right now they are only File Specific which means I will have to manually change the utilisation ...
almost 2 years ago in STAAD.Pro 3 Future consideration

Request Omitted Data from IBC/ASCE7 Seismic Load Generator

There is no method, report, or output command available to display the "k" coefficient used by the program for vertical distribution of seismic base shear per ASCE 7-16, Eq 12.8-2. Since this value can vary with the period it needs to be reported ...
6 months ago in STAAD.Pro 1 Needs review

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
12 months ago in STAAD.Pro 2 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
12 months ago in STAAD.Pro 1 Needs review

Add the design parameters for plate design as a member. In stairs the plate design is very frequently using.

No description provided
over 1 year ago in STAAD.Pro 1 Already exists

Provide detailed calculations and formulas

Can you provide calculations which are similar to the connection design, i.e. include detailed calculations as well as formulas?
about 1 year ago in STAAD.Pro 2 Will not implement

mass Load generator in Physical Modeller

It would be useful if Mass Model generator is included in physical Modeller.
about 1 year ago in STAAD.Pro 1 Needs review