Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 426

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
over 1 year ago in STAAD.Pro 5 Needs review

OpenSTAAD function to turn on members stress ratio.

To streamline the design process using the OpenSTAAD function, we aim to automate the visualization of member stress ratios for each analysis. Currently, when employing the "objOpenSTAAD.View.SetModeSectionPage 1, 6, 19" function, the stress ratio...
over 1 year ago in STAAD.Pro 2 Future consideration

Improve beam/node selection for reporting loads

Add some kind of functionality to categorize "connection types" to simplify reporting of loads. While there is functionality to group members and to group nodes, there is no way to overlap them. When I want the connection loads for certain members...
9 months ago in STAAD.Pro 6 Needs review

Add IS 3370 in Staad CE, RCDC,RAM and staad foundation advance

For analysis of water retaining structure as per IS 3370,staad CE doesn't support IS3370
over 2 years ago in STAAD Concrete 2 Needs review

IS800:2007 result from multiple design blocks

Currently, if there are multiple design blocks present in a STAAD model, in the post-processing utilization table, design ratio from the last design block is reported. It is very common to define multiple design blocks with different set of parame...
over 2 years ago in STAAD.Pro 1 Future consideration

Automate the option of dynamic wave pressure

There is a webinar for modelling, analysis and design of rcc rectangular water retaining structure along with impulsive and convective wave pressure on coffee corner, but there are some limitations and assumptions, like the xml templates are only ...
over 2 years ago in STAAD.Pro 4 Will not implement

Structure discontinuties not allowed for dynamic analysis

Structure discontinuties provided for thermal expansion isn't allowed in dynamic analysis, so provide feature so that we can analyse such structure without separating the model in individual file..
over 2 years ago in STAAD.Pro 2 Already exists

Include a Quick button to "Un-assign" or "remove assigned" Loads from Member/ Elements

Hello Development Team, Could you consider adding a quick "button" to execute "un-assign" or " remove load " command from both plate elements & line members ? (Please refer to the attached picture). This tool would work as a quick "reverse ope...
10 months ago in STAAD.Pro 1 Already exists

Design Lacing and battening column to IS800:2007

Widely used in industry
over 2 years ago in STAAD.Pro 4 Future consideration

CANTILEVER SLAB IN RCDC

Design of cantilever slab in RCDC should be added and also slab supported by beams on its two sides and its other two sides free or only three sides are supported by beams and the other side free.
about 4 years ago in STAAD Concrete 1 Needs review