Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

STAAD.Pro

Showing 440

Design Lacing and battening column to IS800:2007

Widely used in industry
almost 3 years ago in STAAD.Pro 5 Future consideration

Full integration with AutoPIPE and STAAD

Pipelink is quite rudimentary. It does not provide the ability to assign guide supports to different nodes. For example, horizontal loads need to be applied to Vertical Members, while vertical loads need to be applied to Horizontal Members. The sa...
about 1 year ago in STAAD.Pro 3 Needs review

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions
about 1 year ago in STAAD.Pro 1 Needs review

Report for pictures of the structure.

Staad should have one option which helps to create a report of node labels ( tier/levewise) for whole structure. Also a report of beam labels ( tier / levelwise) for the whole structure. Also report of section property ( tier/levelwise) for whole ...
about 3 years ago in STAAD.Pro 1 Will not implement

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
about 1 year ago in STAAD.Pro 1 Will not implement

AI Assistant in Staad.Pro

The possibility of adding an 'AI Assistant' type tool, for example: "Alexa" or "Siri", which with natural language is able to interpret what the user asks for and execute the orders requested.
about 1 year ago in STAAD.Pro 1 Will not implement

Scale factor for displacement quantities in response spectrum analysis as per IS 1893:2016 amendment no-2 (additional clause 7.7.3.2) regarding

It is understood that while performing response spectrum analysis, the scale factor (V_b/V_B ) Where,V_b=Equivalent static base shear,〖 V〗_B Response spectrum base shear), is automatically accounted for calculation of design base shear. But,this s...
about 1 year ago in STAAD.Pro 0 Needs review

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
about 2 years ago in STAAD.Pro 1 Already exists

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
about 2 years ago in STAAD.Pro 5 Needs review

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
about 1 year ago in STAAD.Pro 1 Future consideration