Canadian Seismic Load per 2015 NBC code parameters

Would like to get implemented NBC 2015 Code parameter.
about 1 year ago in STAAD.Pro 0 Future consideration

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
about 1 year ago in STAAD.Pro 1 Needs review

Modeling of trapezoidal pattern raft foundation in staad foundation advance

Staad foundation advance (SFA) has an option to assign plates of various thickness, but it should also have an option to model such plates in TRAPEZOIDAL PATTERN as shown in below images,which is frequently used to model raft foundation, also plac...
about 1 year ago in STAAD Concrete 0 Needs review

Rigid diaphragm on inclined floor/pitched floor/roof

Staad pro doesn't support for modelling of rigid diaphragm for inclined floor/inclined slab/inclined roof, so that response spectrum analysis can not be achieved in this case, so it is necessary to implement feature of modelling rigid diaphragm/se...
about 1 year ago in STAAD.Pro 1 Already exists

Design of Column with basement shear wall in RCDC

When the basement shear wall is modelled along with intermediate columns as shown in image, and such columns supposed to designed in RCDC , then RCDC devides the length of columns into small length/small segments as per meshing of adjacent shear w...
about 1 year ago in STAAD Concrete 3 Needs review

Do not Auto split the design parameter & loadings.

When dealing with a substantial number of members within a STAAD model, the design parameters tend to split automatically. Consequently, this automatic splitting poses challenges when attempting to review the design parameters. The same situation ...
over 1 year ago in STAAD.Pro 1 Future consideration

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review

IMPORT FLOOR SLAB (ANALYSED PLATE ) FROM STAAD PRO TO RCDC FOR DESIGNING

It would be helpfull if modeled floor slab analysed in STAAD.Pro to be imported in RCDC for designing
over 1 year ago in STAAD Concrete 0 Needs review

The STAAD.Pro model import to SACS

Now we can calculate the upstructure in STAAD.Pro for ocean engineer; But the pile will be designed in SACS for sea ice load and wave load. when the model is imported to SACS, the load will loss and need to apply load again in SACS. The workload i...
10 months ago in STAAD.Pro 1 Needs review

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
over 1 year ago in STAAD Concrete 1 Needs review