Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 498

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review

IMPORT FLOOR SLAB (ANALYSED PLATE ) FROM STAAD PRO TO RCDC FOR DESIGNING

It would be helpfull if modeled floor slab analysed in STAAD.Pro to be imported in RCDC for designing
over 1 year ago in STAAD Concrete 0 Needs review

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
over 1 year ago in STAAD Concrete 1 Needs review

The STAAD.Pro model import to SACS

Now we can calculate the upstructure in STAAD.Pro for ocean engineer; But the pile will be designed in SACS for sea ice load and wave load. when the model is imported to SACS, the load will loss and need to apply load again in SACS. The workload i...
11 months ago in STAAD.Pro 1 Needs review

Turkish Building Earthquake Code 2018 and TS 500

Türkiye de yaşayan mühendislerin programlarınızı kendi ülke standart ve kurallarına göre daha rahat kullanabilmeleri ve bunun paralelinde programlarınızın kullanım oranlarının artması doğrultusunda eklenmesi yaralı olacaktır.
11 months ago in STAAD.Pro 4 Future consideration

Turkish Building Earthquake Code 2018 for steel structures

Betonarme binaların projelendirmesi ile birlikte çelik binaların projelendirilmesinde de kendi ülke standart ve kurallarını kullanmak, mühendislerimiz için kolaylık ve rahatlık sağlayacak, programlarınızın ülkemiz içerisinde kullanımının yaygınlaş...
11 months ago in STAAD.Pro 3 Needs review

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
almost 2 years ago in STAAD.Pro 3 Future consideration

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
almost 2 years ago in STAAD.Pro 7 Future consideration

Consider IS:3370 in RCDC for water tank design.

Currently RCDC works only in Euro code for water tank.. my suggestion is please consider IS:3370 for water tank design.
almost 2 years ago in STAAD Concrete 1 Needs review

Waffle /Grid slab and flat slab

Heavy loaded structures...
over 2 years ago in STAAD.Pro 3 Future consideration