Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
about 1 year ago in STAAD.Pro 4 Future consideration

CONCRETE BEAM WITH A HOLE IN STAAD PRO

As we know in R.C structures we may need to provide holes in beam for service purposes. I am here attaching a book showing examples on the design of beams with holes. [View:/cfs-file/__key/telligent-ideas/03d5f738-7ee6-4ff2-9384-201f3d5dd0d9/Concr...
over 3 years ago in STAAD.Pro 1 Future consideration

Ability to Revert to Old Report Format within Staad

The new report formatting while nice in appearance is cumbersome, not quick to use and has issues with savings....can't there be an ability for staad users to "revert" back to the old school report formatting?
7 months ago in STAAD.Pro 1 Needs review

Don't spoil Staad.Pro by implementing weird ideas

I chose this "add idea" route because I couldn't find another channel to communicate my disappointment as stated below. Report setup in STAAD. Pro 2024 is not good. It gives poor quality picture compared to previous versions. This kind of weird pr...
7 months ago in STAAD.Pro 2 Already exists

Incorporate ACI-350 into RCDC

HDR designs many concrete water tanks (round and square). We use STAAD to generate a FEM mesh and then use the stresses to design the concrete elements with load factors unique to ACI-350.
almost 2 years ago in STAAD Concrete 4 Needs review

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
about 1 year ago in STAAD.Pro 2 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
about 1 year ago in STAAD.Pro 1 Needs review

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3?

Hi, I am wondering when STAAD RCDC would be equipped with CSA A23.3? Thanks
almost 2 years ago in STAAD Concrete 0 Needs review

Provide detailed calculations and formulas

Can you provide calculations which are similar to the connection design, i.e. include detailed calculations as well as formulas?
about 1 year ago in STAAD.Pro 2 Will not implement

mass Load generator in Physical Modeller

It would be useful if Mass Model generator is included in physical Modeller.
about 1 year ago in STAAD.Pro 1 Needs review