Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 543

It would be nice to be able to list the allowable stress in a report

SAMPLE BUCKLING LENGTH ALLOWABLESTRESS MEMB LY(m) LZ(m) UNL(m) KY KZ UNF FA(N/mm2) FT(N/mm2) FCZ(N/mm2) 1001 1.000 2.000 1.000 1.000 1.000 1.000 93.400 156.670 138.250 1002 2.500 5.000 2.500 1.000 1.000 1.000 93.400 156.670 138.250 1003 4.000 8.00...
about 2 years ago in STAAD.Pro 1 Future consideration

UC summary based on Profile Shape and Group

Please prepare a UC summary table Profile size wise, Group Wise from ejoumale.pajamale@technipenergies.com
about 2 years ago in STAAD.Pro 1 Needs review

Add SPAN command similar to SACS instead of DJ1 and DJ2

It is painful task to add DJ1 and DJ2 for deflection check in design paramter. Instead create SPAN command , which allows to add a set of members in a SPAN command to calculation local y and z deflection and actual DFF against allowable DFF. This ...
about 2 years ago in STAAD.Pro 2 Future consideration

Orientation check for Solids

It shall be noted that, if solids are not oriented properly than, we are not able to assign properties to the model, and it is difficult to see which the bod is solid. -- With Regards. Ankur Jain -- Model Attached is confidential.
about 2 years ago in STAAD.Pro 1 Needs review

Wind Load Graphic

Product: STAAD.Pro Description: Wind Load Graphic Details: Service Request 7001551689 created from the web by Milton Manos User Phone Number: 17406859217 I am requesting that STAAD.pro add a Wind Load Graphic (see enclosed example) to their calcul...
about 2 years ago in STAAD.Pro 1 Already exists

Add support for Brazilian Codes

Please, add Brazilian codes: Some of the most important codes: ABNT-NBR 6118 (concrete design) ABNT-NBR 6122 (foundations design) ABNT-NBR 8800 (hot-rolled steel design) ABNT-NBR 14762 (cold-formed steel design) ABNT-NBR 7190 (wood design) ABNT-NB...
about 2 years ago in STAAD Concrete 4 Needs review

Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC | STAAD

In RCDC we are using 2 types of Design Codes Combinations like this. IS 456 + IS 13920-1993 IS 456 + IS 13920-2016 Can't we have Third Design Code IS 456 + IS 13920-1993 + IS 13920-2016 in RCDC (SACD) or STAAD Pro like this? Because In IS 456 w...
over 4 years ago in STAAD Concrete 1 Needs review

STEEL ROD AS BRACING IN STAAD PRO CONNECT EDITION

I have model my truss and i want to add steel rod of 20mm diameter as a bracing on pipes carrying the truss, is this option available in Staad Pro Connect Edition?
over 4 years ago in STAAD.Pro 1 Already exists

FLAT SLAB, WITHOUT BEAMS

Option for modelling, analysis and design of a project with flat slab should be added in Staad Pro Connect Edition
over 4 years ago in STAAD.Pro 1 Already exists

Creation of Grid system & creation of views by Grid mark nos

I would suggest to add Grid system at column bases and also create floor levels. This would help us to isolate the grid views & floor levels during the time of geometric modelling.
over 4 years ago in STAAD.Pro 3 Already exists