In Staad Pro 23.00.02.361, the size of the local coordinate system arrow cannot be enlarged or reduced simultaneously with the model. At present, the size of the local coordinate system arrow is too large. When there are many rod elements in the model, the local coordinate system almost covers the entire model, affecting other operations. Please provide improvement.
No description provided
about 1 year ago
in STAAD.Pro
1
Will not implement
Implement unity check of capacity for aluminum members according EN 1999-1-1
It should work similarly to code checking steel members according to EN 1993-1-1. It would benefit everyone designing aluminum structures due to highly corrosive environments and/or weight restrictions.
about 1 year ago
in STAAD.Pro
1
Future consideration
Extrude the current element to the next 'dimensional' element.
at present in the 'Translational repeat' command we have the option to 'link elements' so as to create new 'beam' elements... - could we expand this feature so that: 1) translational repeating a line (parallel to its local X axis) can have the pos...
Add New Zealand concrete design (NZS 3101) to Staad Pro
These could be used when performing member or shell design in STAAD.Pro, as well as Advanced Concrete design.
See applicable snapshots attached. User would like to be able to do design to NZ codes in STAAD.Pro (specifically concrete and timber,...
over 2 years ago
in STAAD.Pro
2
Future consideration
dear teams,please make corrects for software when you design water tank with slab including beams,RCDC not reading beams,plz correct it,thanks in advance
over 2 years ago
in STAAD.Pro
1
Will not implement
Reports: Add Block for Descriptive Title, as before Ver. 23.0
Versions previous to 23.0 allowed a descriptive title in the header block. Now the reader has no clue what the report is about, except maybe by the file name. See attached file which shows descriptive title, right up front where you expect it.
Distinct OpenSTAAD objects for each instance of Staad
At present only one OpenSTAAD object can be retrieved which acts globally for the Staad application which limits the efficient use of Staad. With the ever increasing system resources, having distinct OpenSTAAD objects for each instance of Staad wi...
The ability to add reference labels to geometry (or note), so when the whole model is displayed you can have visual reference of what each item represents, ie label gridlines, elevations
OSLoadUI::CreateLoadEnvelop function name is wrong
Please refer to the snapshot attached. The OSLoadUI::CreateLoadEnvelop function name is wrong. Please update in the next releases. Initially I could not find this function in the intellisense (by typing Create and left me wondering) and hence I am...
about 1 year ago
in STAAD.Pro
1
Will not implement