Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 373 of 373

Modify design parameter "PROFILE"

Design Parameter "PROFILE" seems to check only first 3 characters. If I understand correctly, STAAD already selects the lightest section only for the same kind of section as the current one, and the limit on the height can be set by variables DMAX...
5 days ago in STAAD.Pro 2 Planned

Design of foundation with Shear links in staad foundation advance SFS

Design of foundation with shear link is not available in staad foundation advance (SFA). It is very necessary to implement the design of various foundation/s along with shear link design options also. Especially as per Indian standard codes.
3 days ago in STAAD Concrete 0 Needs review

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
6 days ago in STAAD.Pro 3 Future consideration

Tables with inbuild worksheet like sorting facilities

When sorting information in a worksheet, you can rearrange the data to find values quickly. You can sort a range or table of data on one or more columns of data. you can sort load cases in display tables for both input and output data directly in ...
6 days ago in STAAD.Pro 1 Already exists

Automatic Plate Meshing

Set parameters and have the program create a plate mesh automatically for finite element analysis.
13 days ago in STAAD.Pro 5 Already exists

NSCP 2022 Philippines Seismic Load(similar to ASCE 7-10) addition

Requesting to add NSCP 2022 Philippines Seismic Load(similar to ASCE 7-10) addition to STAAD.Pro. Xstructures can provide all formula and technical documentation
6 months ago in STAAD.Pro 4 Future consideration

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
19 days ago in STAAD.Pro 1 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
21 days ago in STAAD.Pro 1 Needs review

STAAD PRO TO 3D PDF

There should be a way to convert STAAD model to 3D pdf. It will become easy for designers to hover over the model and get clear view of the geometry while modelling in 3D softwares. Inspite of inputs provided, they will have access to 3D pdf where...
about 1 month ago in STAAD.Pro 4 Already exists

Update of Canadian Code CSA 23.3 in STAAD Pro

For the design of concrete structures and foundations that will require permit approval in Canada, a recent code is expected. CSA code available in STAAD Pro Connect Edition is still CSA 23.3-94. Currently the latest code is 2019 but the 2014 is a...