Add an option for optimize to specify equal leg angles.

It would be nice to tell the optimizer to optimize to angles where the angle legs are equal. By default I prefer to specify equal legs, as it eliminates confuse and chances of error when the legs are the same size. So even if the optimizer suggest...
4 months ago in STAAD.Pro 0 Needs review

Is there any possibility to update IS 802 latest code in stadd pro connect in near future?

Is there any possibility to update IS 802 latest code in stadd pro connect in near future? Till now IS 802 1995 is provided instead of IS 802 2016
4 months ago in STAAD.Pro 0 Needs review

Water Tank design as per IS codes in RCDC

No description provided
almost 2 years ago in STAAD Concrete 1 Needs review

COMBINED FOOTING AND MAT/RAFT FOUNDATION FROM SFA TO RCDC FOR DETAILING

I would suggest SFA to add an option exporting designed combined footing and raft foundation to RCDC for detailing as we know RCDC is powerfully in producing structural drawings
about 2 years ago in STAAD Concrete 1 Needs review

Wind Loads on Steel Structures

I think the wind load application should be rewritten to make it simpler and more user friendly. STAAD is at least three times as long as SAP2000 when inputting wind loads.
almost 2 years ago in STAAD.Pro 12 Needs review

OpenSTAAD Function to Retrieve the Id (Not GUID) of a Parametric Surface

As most of the functions exposed in OpenSTAAD uses the surfaceId to target a specific parametric surface, a function to retrieve the Id of the parametric surface by specifying it's name will be essential. I tried using the existing function GetPar...
4 months ago in STAAD.Pro 0 Needs review

OpenSTAAD Function to Retrieve all Existing Parameteric Surfaces' Names

Usually we start creating the parametric surface mesh by assigning a name. However, there will be situations where we need to clear all the existing mesh definitions and then start afresh. It will be much helpful if there is a function in OpenSTAA...
4 months ago in STAAD.Pro 0 Needs review

RCDC enable read incline floor beam

No description provided
over 3 years ago in STAAD Concrete 0 Needs review

Automatic combinations should only include notional loads in the direction of the main lateral load

Hello, There’s no point in applying the notional load against other lateral loads. In STAAD, it’s possible that the Load Combination where automatically generated so the notional loads are generated for all directions even if they countermeasure t...
over 1 year ago in STAAD.Pro 2 Needs review

property reduction factor for plates

dear staad pro team,i think more important things for shar wall system building for high rise building is property modifires for wall,it is misssing in staad pro i dont know why?all softwares have this important feature why is missing in staad?
over 1 year ago in STAAD.Pro 6 Needs review