Do not Auto split the design parameter & loadings.

When dealing with a substantial number of members within a STAAD model, the design parameters tend to split automatically. Consequently, this automatic splitting poses challenges when attempting to review the design parameters. The same situation ...
over 1 year ago in STAAD.Pro 1 Future consideration

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
4 months ago in STAAD.Pro 1 Future consideration

RCDC enable read incline floor beam

No description provided
almost 3 years ago in STAAD Concrete 0 Needs review

New staad module for all types of tank design

All professional, practicing engineers would benefitted. One click analysis and one click reinforcements design of any types of tank UG/elevated of any shapes like RCDC.
over 2 years ago in STAAD.Pro 4 Already exists

IMPORT FLOOR SLAB (ANALYSED PLATE ) FROM STAAD PRO TO RCDC FOR DESIGNING

It would be helpfull if modeled floor slab analysed in STAAD.Pro to be imported in RCDC for designing
over 1 year ago in STAAD Concrete 0 Needs review

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
over 1 year ago in STAAD Concrete 1 Needs review

HAT SECTION WITH LIPS

Kindly make provision for Hat section with Lips( straight lip and inclined lip) in the section database. Please make it such a way that if we enter the depth, width, thickness and give "generate" and all the properties gets generated automatically...
almost 2 years ago in STAAD.Pro 4 Future consideration

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
over 1 year ago in STAAD.Pro 3 Future consideration

Water Tank design as per IS codes in RCDC

No description provided
over 1 year ago in STAAD Concrete 1 Needs review

property reduction factor for plates

dear staad pro team,i think more important things for shar wall system building for high rise building is property modifires for wall,it is misssing in staad pro i dont know why?all softwares have this important feature why is missing in staad?