Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 484 of 484

SFA Foundation use uniform (average) Effective Bearing Pressure per AASHTO 10.6.1.4

Currently, SFA uses the highest corner pressure to design the foundation size bearing on soil. Please revise the SFA program to have an option for a soil supported foundation (versus a rock supported foundation) and provide revised foundation sizi...
over 1 year ago in STAAD Concrete 2 Needs review

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
over 1 year ago in STAAD.Pro 3 Future consideration

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
over 2 years ago in STAAD.Pro 1 Future consideration

Slab deflection plots

Currently the only way to check the deflection of a slab is to review the deflected shape of the shells' mesh, or in the tabulated results. It would be very useful if the contour plots for shells included the option to contour deflections as well ...
over 1 year ago in STAAD.Pro 2 Future consideration

RCDC design all type footing

make RCDC design all type footing(single,combine,mat......)combine (RCDC,RCDC FE and staad advance foundation)
over 3 years ago in STAAD Concrete 1 Needs review

Combined profile of a wide flange and channel as a single object

For Inclusion of built up section in standard I section combination with Channel section on top flange, which is widely used for gantry girder.
over 1 year ago in STAAD.Pro 5 Already exists

In India we are using HAT section with lip but in staad pro we are not able design this section and it create lots of problem to all users in India to convince clients. So, Please add this section property in your section database.

No description provided
6 months ago in STAAD.Pro 1 Will not implement

Direct Analysis Method with Tension-Only members

Just as the title. To be able to analyze a structure with Tension-Only members using the Direct Analysis Method.
almost 2 years ago in STAAD.Pro 1 Future consideration

COMBINED FOOTING, RAFT FOOTING IN RCDC

May you please include the design of raft foundation and combined footing in RCDC
over 4 years ago in STAAD Concrete 1 Needs review

Moving Loads Acting in Horizontal Directions

Provide the ability to have horizontal moving loads in addition to the vertical loads. For example, ASCE 7 requires cranes to be designed for vertical loads and horizontal loads. It would be great if STAAD had the ability to have both the vertical...
about 2 years ago in STAAD.Pro 3 Future consideration