Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
about 2 years ago in STAAD.Pro 3 Future consideration

COMBINED FOOTING AND MAT/RAFT FOUNDATION FROM SFA TO RCDC FOR DETAILING

I would suggest SFA to add an option exporting designed combined footing and raft foundation to RCDC for detailing as we know RCDC is powerfully in producing structural drawings
over 1 year ago in STAAD Concrete 0 Needs review

Design of Column with basement shear wall in RCDC

When the basement shear wall is modelled along with intermediate columns as shown in image, and such columns supposed to designed in RCDC , then RCDC devides the length of columns into small length/small segments as per meshing of adjacent shear w...
10 months ago in STAAD Concrete 3 Needs review

To customize formula or coefficient for Live Load reduction

Now, Staad.Pro includes the option of Reducible Live Load by UBC/IBC. But the formula included is 16-23 instead of 16-22. Also, Staad uses equation 16-23 for load type Live and type Roof Live, instead of using section 1607.11 for Roof Live and equ...
over 1 year ago in STAAD.Pro 2 Future consideration

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
3 months ago in STAAD.Pro 1 Will not implement

Time History in multiple load case for blast loads

For Blast loads in some cases we have to apply blast load in all the direction i.e x and z in different load cases. presently the time history load is possible only in one load case. Time history should be allowed to be added in mutiple load cases
10 months ago in STAAD.Pro 2 Future consideration

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
7 months ago in STAAD.Pro 2 Will not implement

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
11 months ago in STAAD.Pro 4 Needs review

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
7 months ago in STAAD.Pro 1 Needs review

AI Assistant in Staad.Pro

The possibility of adding an 'AI Assistant' type tool, for example: "Alexa" or "Siri", which with natural language is able to interpret what the user asks for and execute the orders requested.
4 months ago in STAAD.Pro 1 Will not implement