implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
9 months ago in STAAD.Pro 2 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
9 months ago in STAAD.Pro 1 Needs review

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
over 1 year ago in STAAD.Pro 7 Future consideration

Automatic combinations should only include notional loads in the direction of the main lateral load

Hello, There’s no point in applying the notional load against other lateral loads. In STAAD, it’s possible that the Load Combination where automatically generated so the notional loads are generated for all directions even if they countermeasure t...
about 1 year ago in STAAD.Pro 2 Needs review

Consider IS:3370 in RCDC for water tank design.

Currently RCDC works only in Euro code for water tank.. my suggestion is please consider IS:3370 for water tank design.
over 1 year ago in STAAD Concrete 1 Needs review

Provide detailed calculations and formulas

Can you provide calculations which are similar to the connection design, i.e. include detailed calculations as well as formulas?
10 months ago in STAAD.Pro 2 Will not implement

mass Load generator in Physical Modeller

It would be useful if Mass Model generator is included in physical Modeller.
10 months ago in STAAD.Pro 1 Needs review

property reduction factor for plates

dear staad pro team,i think more important things for shar wall system building for high rise building is property modifires for wall,it is misssing in staad pro i dont know why?all softwares have this important feature why is missing in staad?
about 1 year ago in STAAD.Pro 6 Needs review

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
about 2 years ago in STAAD.Pro 2 Needs review

Waffle /Grid slab and flat slab

Heavy loaded structures...
over 2 years ago in STAAD.Pro 3 Future consideration