Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 484 of 484

Built-up tapered section name

All tapered section name shows as a tapered . its very useful if staad pro show the tapered section show the section in the display- Tapered I- 300x6+200x8+150x8 if its uniform web depth Tapered I- (300-750)x6+200x8+150x8 if its tapered web depth ...
7 months ago in STAAD.Pro 1 Future consideration

RCDC -Foundation design - Multiple Soil layers and Dispersed soil weight to be considered in the Stability checks -Buoyancy and overturning

For the foundation design, Buoyancy and overturning stability checks are performed. Presently Soil above the footing area is considered for the stability checks. The software should allow the user wants to consider the dispersed soil weight for th...
about 2 years ago in STAAD Concrete 0 Needs review

Spring Support

Spring supports are created only in a particular direction. For e.g. base/soil springs. negative displacement is considered as compression. what if a steel base plate is to be modelled below a concrete slab. There is no way to create a compression...
7 months ago in STAAD.Pro 4 Already exists

Water Tank design as per IS codes in RCDC

No description provided
over 1 year ago in STAAD Concrete 1 Needs review

Steel AutoDrafter: Customized Offset Distance

Steel Auto-Drafter draws member releases with a 20mm offset by default. The user would like to set this offset distance to an arbitrary distance. Additionally, the user would like to set separate distances for each of the following members: ...
over 2 years ago in STAAD.Pro 6 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
over 2 years ago in STAAD.Pro 3 Future consideration

Add tapered rectangular tube section r2

Extend the current tapered tube definition to allow for the specification and analysis of tapered rectangular tube profiles (i..e where the length of the two side dimensions differs). Currently STAAD.Pro supports the definition and analysis of tap...
over 1 year ago in STAAD.Pro 1 Already exists

Calculate section properties when adding new shape to database

Two things here:Have the ability for STAAD (in the physical modeler) to calculate the section properties when entering a new shape into an existing database. For example, I'm adding a new hat channel into the AISI cold formed Profiles database. In...
over 2 years ago in STAAD.Pro 2 Future consideration

COMBINED FOOTING AND MAT/RAFT FOUNDATION FROM SFA TO RCDC FOR DETAILING

I would suggest SFA to add an option exporting designed combined footing and raft foundation to RCDC for detailing as we know RCDC is powerfully in producing structural drawings
about 2 years ago in STAAD Concrete 1 Needs review

Wind Loads on Steel Structures

I think the wind load application should be rewritten to make it simpler and more user friendly. STAAD is at least three times as long as SAP2000 when inputting wind loads.
almost 2 years ago in STAAD.Pro 12 Needs review