Add angle section to ram connnection so that the Lattice structure can be calculated

Add angle section to ram connnection so that the column base node of Lattice structure can be calculated
9 months ago in STAAD.Pro 1 Needs review

Option to input load values in STAAD as a function F(x) where x varies ( e.g x= depth)

In recent times, I have been designing a large number of buried underground structures. (I figured many Engineers may have similar experiences on this too). For buried structures, a few of the applied loads are a function of a single variable i.e....
over 1 year ago in STAAD.Pro 1 Future consideration

Plate Stresses Graphical Contours to be included in QUICK COMMANDS

Could you please add shortcut to view Plate stresses Graphical Contours ( Mx, My, Mxy, SQx, SQy, Sx, Sy) in the Customize quick commands Pop-Up shortcut using space bar. The current function only brings up tables which is a bit cumbersome when mak...
over 1 year ago in STAAD.Pro 4 Future consideration

Eurocode Wind Load Automatic Generation

Please add the ability to automatically generate wind loading to eurocodes.
over 1 year ago in STAAD.Pro 1 Future consideration

Use Center of the Structure as rotation Center

The Orientation Settings window provides the option "Use the center of the structure as the rotation center". However, when i perform the "Display Whole Structure" function, the rotation center is reset to 0,0,0. This happens when the Orientation ...
10 months ago in STAAD.Pro 0 Needs review

Postprocessing display of multiple design blocks for AIJ codes

Currently, it is possible to display results for multiple design blocks with AISC360-16 results only. This feature is also required for AIJ2005 and 2002. In AIJ codes, load cases are classified into parmanent loads, temporary loads and loads for...
over 1 year ago in STAAD.Pro 1 Future consideration

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
over 1 year ago in STAAD.Pro 1 Already exists

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
over 1 year ago in STAAD.Pro 5 Needs review

Add IS 3370 in Staad CE, RCDC,RAM and staad foundation advance

For analysis of water retaining structure as per IS 3370,staad CE doesn't support IS3370
over 2 years ago in STAAD Concrete 2 Needs review

Design of foundation with Shear links in staad foundation advance SFS

Design of foundation with shear link is not available in staad foundation advance (SFA). It is very necessary to implement the design of various foundation/s along with shear link design options also. Especially as per Indian standard codes.
10 months ago in STAAD Concrete 0 Needs review