Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 400 of 400

In Staad Pro 23.00.02.361, the size of the local coordinate system arrow cannot be enlarged or reduced simultaneously with the model. At present, the size of the local coordinate system arrow is too large. When there are many rod elements in the model, the local coordinate system almost covers the entire model, affecting other operations. Please provide improvement.

No description provided
8 months ago in STAAD.Pro 1 Will not implement

RCDC - Allow for rebar designs for sections with failures to investigate existing conditions.

When completing a design in RCDC if the member fails, you cannot edit the rebar. I would like to be able to edit reinforcement. Then after the reinforcement is added, I would like it to print a full report so I can see what is failing. This is so ...
8 months ago in STAAD Concrete 0 Needs review

Implement unity check of capacity for aluminum members according EN 1999-1-1

It should work similarly to code checking steel members according to EN 1993-1-1. It would benefit everyone designing aluminum structures due to highly corrosive environments and/or weight restrictions.
8 months ago in STAAD.Pro 1 Future consideration

Extrude the current element to the next 'dimensional' element.

at present in the 'Translational repeat' command we have the option to 'link elements' so as to create new 'beam' elements... - could we expand this feature so that: 1) translational repeating a line (parallel to its local X axis) can have the pos...
8 months ago in STAAD.Pro 3 Already exists

Reports: Add Block for Descriptive Title, as before Ver. 23.0

Versions previous to 23.0 allowed a descriptive title in the header block. Now the reader has no clue what the report is about, except maybe by the file name. See attached file which shows descriptive title, right up front where you expect it.
8 months ago in STAAD.Pro 2 Needs review

Distinct OpenSTAAD objects for each instance of Staad

At present only one OpenSTAAD object can be retrieved which acts globally for the Staad application which limits the efficient use of Staad. With the ever increasing system resources, having distinct OpenSTAAD objects for each instance of Staad wi...
8 months ago in STAAD.Pro 2 Already exists

Add custom labels to geometry

The ability to add reference labels to geometry (or note), so when the whole model is displayed you can have visual reference of what each item represents, ie label gridlines, elevations
8 months ago in STAAD.Pro 1 Needs review

Add IS 3370 in Staad CE, RCDC,RAM and staad foundation advance

For analysis of water retaining structure as per IS 3370,staad CE doesn't support IS3370
about 2 years ago in STAAD Concrete 2 Needs review

IS800:2007 result from multiple design blocks

Currently, if there are multiple design blocks present in a STAAD model, in the post-processing utilization table, design ratio from the last design block is reported. It is very common to define multiple design blocks with different set of parame...
about 2 years ago in STAAD.Pro 1 Future consideration

display of design results for different design parameters

It is understood that only for AISC 360 design checks, it is feasible to view the design results for different design parameters & maximum case, while the same is not allowed for other design codes without going in to output file. Appreciate t...
over 1 year ago in STAAD.Pro 5 Future consideration