Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 531 of 531

Design of Column with basement shear wall in RCDC

When the basement shear wall is modelled along with intermediate columns as shown in image, and such columns supposed to designed in RCDC , then RCDC devides the length of columns into small length/small segments as per meshing of adjacent shear w...
over 1 year ago in STAAD Concrete 3 Needs review

Please add the following South African Concrete Standards (SANS) to the RCDC (STAAD Advance Concrete Design) Program

Main SA Concrete Design Code SABS 10100-1:2000 Edition 2.2. The Structural use of Concrete Part 1: Design Supplementary SA Concrete Design Codes SABS 10100-2:2014 Edition 3 The Structural use of Concrete Part 2: Materials and Execution of Work SAN...
almost 2 years ago in STAAD Concrete 1 Needs review

Waffle /Grid slab and flat slab

Heavy loaded structures...
almost 3 years ago in STAAD.Pro 3 Future consideration

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
over 1 year ago in STAAD.Pro 4 Needs review

Stress Ratio Results for Multiple Load Cases

Show code check results for more than just the worst case. Should be able to see what the next worst, and next worse after that and so on. It's been over 10 years since I used it but I believe SACS does this. If so, could take a look at it.
almost 2 years ago in STAAD.Pro 3 Future consideration

OpenSTAAD function to extract the capacity of members

OpenSTAAD function to extract the capacity of members, so that it will be used for additional checks as per Code
almost 2 years ago in STAAD.Pro 7 Future consideration

Consider IS:3370 in RCDC for water tank design.

Currently RCDC works only in Euro code for water tank.. my suggestion is please consider IS:3370 for water tank design.
almost 2 years ago in STAAD Concrete 1 Needs review

WIND CORNER PRESSURE AND ROOF IN WIND LOAD GENERATOR

Hello i would like to drop my suggestion for consideration, as we know up to now Wind Load generator, can only generate wind on panels. But during design we may have to apply corner wind pressure especially in connection design and also to apply w...
over 2 years ago in STAAD.Pro 2 Needs review

Add angle section to ram connnection so that the Lattice structure can be calculated

Add angle section to ram connnection so that the column base node of Lattice structure can be calculated
12 months ago in STAAD.Pro 1 Needs review

Hide Selected Object

it is a very useful option when you are trying to hide some selected entity for better view. HIDE SELECTED OBJECT rather than using invert Selection and other ways.
over 1 year ago in STAAD.Pro 1 Already exists