Skip to Main Content
Need Support? Let’s guide you to the right answer or agent.
ADD A NEW IDEA

All ideas

Showing 552 of 552

Design Lacing and battening column to IS800:2007

Widely used in industry
about 3 years ago in STAAD.Pro 5 Future consideration

Report for pictures of the structure.

Staad should have one option which helps to create a report of node labels ( tier/levewise) for whole structure. Also a report of beam labels ( tier / levelwise) for the whole structure. Also report of section property ( tier/levelwise) for whole ...
about 3 years ago in STAAD.Pro 1 Will not implement

Exporting Physical members from Staad Pro to RCDC

Hi I have an exceedingly large model which takes hours to run on RCDC. Also, when the model is exported from STAAD to RCDC, all the beam support points are not detected properly by RCDC and I have to spend days just correcting the Beam Continuum. ...
about 1 year ago in STAAD.Pro 1 Needs review

for RCDC software, Please add the result and calculate about Failed Member to help designer update the model

when I use RCDC, the column failed to crack-width,but I want to know the result of failed column crack-width value and calcute to deside how to update the model, update Longitudinal reinforcement or stirrup
about 1 year ago in STAAD Concrete 0 Needs review

automatic coupling plate element boundary

Need a function similar to Midas automatic coupling plate element boundary
about 1 year ago in STAAD.Pro 1 Already exists

Full integration with AutoPIPE and STAAD

Pipelink is quite rudimentary. It does not provide the ability to assign guide supports to different nodes. For example, horizontal loads need to be applied to Vertical Members, while vertical loads need to be applied to Horizontal Members. The sa...
about 1 year ago in STAAD.Pro 3 Needs review

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions
about 1 year ago in STAAD.Pro 1 Needs review

Lift Permissible Effective length Factor is 5 in RCDC

Currently in Column Design, RCDC has a limit on the maximum value of the effective length factor and users cannot modify this limit value 5. I want RCDC to lift the restriction on this factor. In my case as per attached staad, Column effective len...
about 1 year ago in STAAD Concrete 1 Needs review

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
about 1 year ago in STAAD.Pro 1 Will not implement

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
about 2 years ago in STAAD.Pro 1 Already exists